CC2000 User Manual
210
The device I want to add
cannot be found.
1. Make sure the CC2000 Manager is running and all
services have started successfully.
2. Make sure that CC Management has been enabled
and specified correctly in the device’s ANMS settings.
When adding a Cat5e KVM
switch, can I add all the
ports at the same time?
Yes – provided all the ports have KVM Adapters
attached and their devices are on line. See the note on
page 84, for details.
The icon for my port
indicates the port is online,
but the icon for the device it
belongs to indicates it is
offline. I am unable to
access the device or port.
This indicates that the device’s firmware does not
support this version of the CC2000. Update the device’s
firmware to the latest version.
Devices connected to my
CC2000 slave servers do
not show up in the Master
server’s Available Devices
list.
1. Check to see if the device has already been added. If
it has, it will not show up in the list.
2. Click the Show Available Devices button on each of
the slaves.
3. After trying #2, if the devices don’t show up, check
the device’s ANMS settings to be sure that CC
Management has been enabled and that the IP and
port address of the CC2000 you want the device to
be recognized by has been correctly specified.
4. After trying #2, if the devices do show up, there was
probably a network problem. Perform the Replicate
Database to the Master function. See
.
My ATEN/ALTUSEN device
isn’t being recognized by
the CC2000.
1. The device in question may not be supported by the
, page 199, for a list of
supported devices.
2. The device’s firmware must be upgraded to the latest
version in order to be capable of CC2000
management.
After making a setting
change and clicking Save, a
HTTP Status 500 -
error
page comes up.
You made a mistake when you entered the setting. This
is an Apache Tomcat error message that appears
whenever it receives a setting that makes no sense to it.
To recover, select any other tab and then come back to
make your change – be sure to enter a valid setting.
I set the CC2000 for “No
timeout” operation, but it
timed out anyway.
The change doesn’t take effect until the next time you
log in.
Problem
Resolution
cc2k.book Page 210 Tuesday, December 21, 2010 4:00 PM