Link Lengths
values.
For the robot shown in SCARA Independent, the
Link
Length
values are:
•
L1 = 20
•
L2 = 40
Base offsets and end-effector offsets do not apply to a SCARA Independent robot
configuration.
Use these guidelines when configuring a Cartesian Gantry robot.
See also
Establish the reference frame for a Cartesian Gantry robot
Identify the work envelope for a Cartesian Gantry robot
Define configuration parameters for a Cartesian Gantry robot
For a Cartesian Gantry robot, the reference frame is an orthogonal set of X1, X2,
and X3 axes positioned anywhere on the Cartesian robot. All global coordinate
measurements (points) are relative to this reference frame. Typically, the reference
frame is aligned with the X1, X2, and X3 axes of the machine.
Configure a Cartesian
Gantry robot
Establish the reference frame
for a Cartesian Gantry robot