Manual
TdC 8001
-111-
D-Board time 2
Menu 5
Default = 3 seconds
A time can be set that indicates for how long the second time in second heat (total time or run time)
remains on the display (5) and the display boad before the ranking disappears (or switches back to total
time). This time is called display time 2. It can be set between 0 and 99 seconds.
Menu 4: DISPLAY TIME 2 = 03 S
enter seconds with finish keypad (8)
Save with: ENTER
exit with <ENTER>
Display board baud rate
Menu 19
Default = 2400 Bd
The display board interface can be set to 2400, 4800, 9600 or 19200 baud. When using
ALGE
display
board 2400 baud must be set.
Menu 19: RS232 BAUD RATE
2400 Bd <
F1
4800 Bd
F2
9600 Bd
F3
Save with: ENTER
19200 Bd
F4
D-Board channel 2
Menu 20
Default = running
The output can be set at channel 2 of interface display board (e). Output of running time, stopped time
or best time is possible. A ranking is always output via the display board interface (e) at channel 2.
TdC 8001 sold from 2008:
Pin 1 of DIN plug “display board” (e) is switched over. Banana jack always receive running time.
TdC 8001 sold before 2008:
Switching between channel 1 and 2 can be effected by turning the plug by 180°. Pin 3 receives always
the running time; Pin 3 can be switched over in menu 19. Banana jack is also switchable.
Menu 4: D-BOARD CHANNEL 2
RUNNING
<
F1 output of stopped time
STOPPED
F2 output of running time
BEST TIME
F3 output of best time
Save with: ENTER
confirm with <ENTER>
Brightness of LED display board
Menu 55
Default = 9
When an
ALGE
LED display board is used, the brightness can be adjusted in 10 steps.
Menu 55: LED BRIGHTNESS = 9
input between 0 and 9
0 = dark, 9 = bright
Save with: ENTER
exit with <ENTER>