6.2 Split-Sequential, Program 3
Net timing and lap timing for competitions with single or mass start with any number of competitors in
the competition at the same time (e. g. relay at Nordic skiing). One start, one finish and up to eight
intermediate time channels are available.
Always input the number of laps for split-sequential. When the last stop impulse is reached (last lap,
finish crossing) the time for this competitor does not continue in the display. Every stop impulse except
for the last is shown on the display and the scoreboard for as long as the display time 1 indicates.
256 heats can be executed. When starting a new heat, only the run times of the previous one are
adopted.
You can set if the time starts with 0:00.00 or with the total time of the previous/all previous heats.
In split-sequential no groups can be entered.
Activation procedure:
−
Turn on TdC 8001 (switch g)
−
Enter program number 3 on finish keypad (8), <ENTER>
−
Clear memory for race that is used, <ENTER>
−
Select race
−
Enter number of laps, <ENTER>
−
Select precision, <ENTER>
−
Select start mode, <ENTER>
−
Synchronize device, select synchronization mode with <F1> (if correct display of time of day) or
<F2> (if time of day must be synchronized)
−
Start time of day (with impulse on channel 9 or <START>)
Race procedure with mass start and three laps:
−
No setting possible on keypad (12) for mass starts, start display (1) shows “1”
−
Input start number for finish (finish keypad (8), e. g. StNo. 1)
−
<ENTER>
−
Display (6) must show entered start number 1, display (5) must show time zero
−
Start impulse for all competitors effected (mass start)
−
Display (5) shows running time, display (6) shows start number 1 and 1 for 1
st
lap
−
Display (1) now shows b1 (b = occupied start)
−
Finish impulse for the first lap of start number 1 effected
−
Time stops on display (5) and continues after the display time 1 set in menu 4. Display (6) still
shows start number 1 but the lap counter increased to 2.
−
etc.
−
Finish impulse for second lap of start number 1 effected
−
Time stops on display (5) and continues after the display time 1 set in menu 4. Display (6) still
shows start number 1 but the lap counter increased to 3.
−
etc.
−
Finish impulse for third lap of start number 1 effected.
−
Time stops on display (5). On display (6) start number 1 and lap number 3 are still shown.
Modify times:
A lap time cannot directly be corrected. The lap time is modified when the time of channel 0 or 1 or the
run time is changed.
Channel assignment
c0 = start channel
c1 = lap/end time
c2 = intermediate time
c3 = intermediate time
c4 = intermediate time
c5 = intermediate time
c6 = intermediate time
c7 = intermediate time
c8 = intermediate time
c9 = intermediate time