I ni ti al Con fi gu r atio n
C o m m i ssi o n i n g M an u al
4.
a.
Apply factory defaults to the BSDU by performing the following:
On the toolbar, click the
Set Factory Default
button.
A Warning message box appears.
Figure
3-6: Warning message box for setting defaults
b. Click
Yes
to confirm applying factory defaults to the device.
A Warning message box appears, requesting you to confirm device reset.
Figure
3-7: Warning message box for resetting device
c.
5.
Click Yes to reset the device with default settings.
WipConfig applies default settings to the BSDU.
In the Network
Configuration
group, enter the following fields:
Eth IP Address:
BSDU’s IP address (e.g.
10.0.0.5
)
Eth Subnet Mask
: BSDU’s subnet mask address (e.g.
255.255.255.240
)
Default Gateway
: BSDU’s default gateway’s IP address, if relevant
3-10
Airspan Networks Inc.
01040311-07