Consumables and Parts for General GC Maintenance
lists consumable parts for the hydrogen sensor module
accessory and for general GC maintenance.
Table 2
G3447A Hydrogen Sensor Module Accessory parts
Description
Part number
Hydrogen sensor parts
Calibration gas cylinder, 2 percent hydrogen gas in 17 L compressed air
5190-6890
Cylinder stand with locking screw
1400-3583
Pressure regulator, with gage
G3440-80153
Fittings and hardware
Fittings kit, 1/8-in. brass, 20/pk
5080-8750
Plug, 1/8-in. brass 6/pk
5180-4124
Tee, 1/8-in. brass 2/pk
5180-4160
Union, 1/8-in. brass 2/pk
5180-4127
Cross, union 1/8-in. brass
0100-0161
GC Supply Gas Installation Kit with Gas Purifiers
19199N
Installation kit for GCs without gas purifiers
19199M
PTFE tape
0460-1266
Copper tubing, 1/8-in. 12 ft.
5021-7107
Copper tubing, 1/8-in. od, 50 ft
5180-4196
Gas regulators
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA350,
hydrogen, argon/methane, with 1/8-in. fitting. For 1/4-in. tubing purchase a 1/4-in.
adapter.
5183-4642
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA346, air,
with 1/8-in. fitting. For 1/4-in. tubing purchase a 1/4-in. adapter.
5183-4641
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA590,
industrial air, with 1/8-in. fitting. For 1/4-in. tubing purchase a 1/4-in. adapter.
5183-4645
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA580,
helium, argon, nitrogen, 1/8-in. fitting. For 1/4-in. tubing purchase a 1/4-in. adapter.
5183-4644
Regulator, 2-stage, brass body, stainless steel diaphragms, 125 psi max, CGA540,
oxygen, 1/8-in. fitting. For 1/4-in. tubing purchase a 1/4-in. adapter.
5183-4643
Gas Clean Filters
Gas Clean connecting unit, 1-position), 1/4-in.
CP7980
Gas Clean connecting unit, 1-position), 1/8-in.
CP7988
Gas Clean connecting unit, 2-position), 1/4-in.
CP738406
Gas Clean connecting unit, 2-position), 1/8-in.
CP738407
Connect unit, Gas Clean, 4 filter, 1/4-in., 1/pk
CP7989
Summary of Contents for Agilent 7890 Series
Page 1: ...Agilent Technologies Agilent 7890 Series Gas Chromatograph Maintaining Your GC ...
Page 28: ...28 Maintaining Your GC 3 Maintaining the GC ...
Page 74: ...74 Maintaining Your GC 6 Maintaining the Purged Packed Inlet 1 2 mm ...
Page 100: ...100 Maintaining Your GC 6 Maintaining the Purged Packed Inlet ...
Page 126: ...126 Maintaining Your GC 7 Maintaining the COC Inlet ...
Page 150: ...150 Maintaining Your GC 8 Maintaining the MMI ...
Page 176: ...176 Maintaining Your GC 9 Maintaining the PTV Inlet ...
Page 186: ...186 Maintaining Your GC 10 Maintaining the VI ...
Page 194: ...194 Maintaining Your GC 10 Maintaining the VI ...
Page 208: ...208 Maintaining Your GC 11 Maintaining the FID ...
Page 258: ...258 Maintaining Your GC 13 Maintaining the uECD ...
Page 271: ...Maintaining the NPD 14 Maintaining Your GC 271 ...
Page 288: ...288 Maintaining Your GC 14 Maintaining the NPD ...
Page 306: ...306 Maintaining Your GC 15 Maintaining the FPD ...
Page 328: ...328 Maintaining Your GC 17 Maintaining the Aux EPC ...
Page 334: ...334 Maintaining Your GC 18 Maintaining the PCM ...
Page 348: ...348 Maintaining Your GC 19 Maintaining a Valve ...
Page 353: ...Swagelok Connections 20 Maintaining Your GC 353 Figure 14 Completed fitting ...