![Agilent Technologies Agilent 7890 Series Maintenance Manual Download Page 178](http://html.mh-extra.com/html/agilent-technologies/agilent-7890-series/agilent-7890-series_maintenance-manual_2867996178.webp)
178
Maintaining Your GC
10
Maintaining the VI
Consumables and Parts for the VI
See the Agilent catalog for consumables and supplies for a
more complete listing, or visit the Agilent Web site for the latest
information (
Table 25
Parts for the VI
Description
Part number
Clamping plate
G2319-20540
Volatiles interface
G2319-60505
Long column nut (65 mm)
G3504-20504
Nut, for transfer, pressure sensing, or
split vent line
19258-20830
Ferrule, for transfer, pressure sensing,
or split vent line
19258-20870
Split vent trap PM kit, single cartridge
5188-6495
Table 26
Nuts, ferrules, and hardware for capillary columns
Column id (mm)
Description
Typical use
Part number/quantity
.530
Ferrule, Vespel/graphite,
0.8-mm id
0.45-mm and 0.53-mm capillary
columns
5062-3512 (10/pk)
Ferrule, graphite, 1.0-mm id
0.53-mm capillary columns
5080-8773 (10/pk)
Ferrule, graphite, 0.8-mm id
0.53-mm capillary columns
500-2118 (10/pk)
Column nut, finger-tight (for
0.53-mm columns)
Connect column to inlet or detector
5020-8293
.320
Ferrule, Vespel/graphite,
0.5-mm id
0.32-mm capillary columns
5062-3514 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and
0.32-mm capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector
5020-8292
.250
Ferrule, Vespel/graphite,
0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm
capillary columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id
0.1-mm, 0.2-mm, 0.25-mm, and
0.32-mm capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector
5020-8292
Summary of Contents for Agilent 7890 Series
Page 1: ...Agilent Technologies Agilent 7890 Series Gas Chromatograph Maintaining Your GC ...
Page 28: ...28 Maintaining Your GC 3 Maintaining the GC ...
Page 74: ...74 Maintaining Your GC 6 Maintaining the Purged Packed Inlet 1 2 mm ...
Page 100: ...100 Maintaining Your GC 6 Maintaining the Purged Packed Inlet ...
Page 126: ...126 Maintaining Your GC 7 Maintaining the COC Inlet ...
Page 150: ...150 Maintaining Your GC 8 Maintaining the MMI ...
Page 176: ...176 Maintaining Your GC 9 Maintaining the PTV Inlet ...
Page 186: ...186 Maintaining Your GC 10 Maintaining the VI ...
Page 194: ...194 Maintaining Your GC 10 Maintaining the VI ...
Page 208: ...208 Maintaining Your GC 11 Maintaining the FID ...
Page 258: ...258 Maintaining Your GC 13 Maintaining the uECD ...
Page 271: ...Maintaining the NPD 14 Maintaining Your GC 271 ...
Page 288: ...288 Maintaining Your GC 14 Maintaining the NPD ...
Page 306: ...306 Maintaining Your GC 15 Maintaining the FPD ...
Page 328: ...328 Maintaining Your GC 17 Maintaining the Aux EPC ...
Page 334: ...334 Maintaining Your GC 18 Maintaining the PCM ...
Page 348: ...348 Maintaining Your GC 19 Maintaining a Valve ...
Page 353: ...Swagelok Connections 20 Maintaining Your GC 353 Figure 14 Completed fitting ...