KNX control elements and application parameters
Control element "Audio control"
Product manual 2CKA00xx73xxxxx
│
176
The parameter is used to send the command of the pause button with "0" or "1".
-
1-byte value [0 - 255]
: The value of a pause button is sent as 1-byte value without a
sign. The following supplementary parameter is available:
Value for pause
:
Options:
Setting option from 0 - 255
The parameter is used to send the value of the pause button as absolute value.
10.14.6 Use of stop button
Options:
Deactivated
Activated
–
Deactivated
: No stop button is enabled. No additional parameters available.
–
Activated
: The stop button is enabled. The following supplementary parameter is available:
Object type stop button
:
Options:
1 bit
1-byte value [0 - 255]
The parameter is used to specify the size of the communication object for sending
telegrams.
– 1
bit
: Commands of a stop button are sent with 1 bit (0 or 1). The following
supplementary parameter is available:
Value for stop
:
Options:
0
1
The parameter is used to send the command of the stop button with "0" or "1".
-
1-byte value [0 - 255]
: The value of a stop button is sent as 1-byte value without a sign.
The following supplementary parameter is available:
Value for stop
:
Options:
Setting option from 0 - 255
The parameter is used to send the value of the stop button as absolute value.
10.14.7 Use of forward button
Options:
Deactivated
Activated
–
Deactivated
: No forward button is enabled. No additional parameters available.
–
Activated
: The forward button is enabled. The following supplementary parameter is
available: