KNX control elements and application parameters
Operation of "RGBW" control element“
Product manual 2CKA00xx73xxxxx
│
128
The parameter is used to specify the On/Off control.
–
Switch object
: Setting, when the lamp contains a "Switch" object. The following
supplementary parameters are available:
Switched On -> preset value:
Options:
Deactivated
Activated
–
Deactivated
: No presets are sent when the lamp is switched on.
–
Activated
: The stored presets are sent when the lamp is switched on.
Switched Off -> RGB value 0,0,0:
Options:
Deactivated
Activated
–
Deactivated
: No RGB values are sent when the lamp is switched off.
–
Activated
: The RGB values (0,0,0) are sent when the lamp is switched off. This
parameter is important for lamps that do not contain a "Switch" object.
–
RGB feedback
: Setting when the lamp contains no "Switch" object but is switched off via
the RGB values.
–
RGB+W
: Used for RGB lamp with integrated white component. The following
supplementary parameters are available:
Switching On/Off via:
Options:
1 object
2 objects
The parameter is used to specify the On/Off control.
–
1 Object
: Setting when the lamp has only one channel (e.g. Philips Hue).
–
2 Objects
: Setting when the lamp has several channels (RGB and White separated, e.g.
two stripes), separate ON/OFF switching via data points.
Switched On -> preset value:
Options:
Deactivated
Activated
–
Deactivated
: No presets are sent when the lamp is switched on.
–
Activated
: The stored presets are sent when the lamp is switched on.
Switched Off -> RGB value 0,0,0:
Options:
Deactivated
Activated
–
Deactivated
: No RGB values are sent when the lamp is switched off.
–
Activated
: The RGB values (0,0,0) are sent when the lamp is switched off. This
parameter is important for lamps that do not contain a "Switch" object.
-
RGB+WW/CW
: Use for RGB lamp with integrated warm white and cold white component.
The following supplementary parameters are available: