Table of contents
Product manual 2CKA00xx73xxxxx
│
10
10.24.36
Temperature reading — Inputs of weighted temperature reading .............................................223
10.24.37
Temperature reading — Weighting of internal measurement (0 to 100%) .................................224
10.24.38
Temperature reading — Weighting of external measurement (0 to 100%) ................................224
10.24.39
Temperature reading — Weighting of external measurement 2 (0 to 100%) .............................224
10.24.40
Temperature reading — Cyclic sending of the actual temperature (min) ...................................224
10.24.41
Temperature reading — Difference of value for sending the actual temperature (x 0.1°C) ........225
10.24.42
Temperature reading — Adjustment value for internal temperature measurement (x 0.1°C) ....225
10.24.43
Temperature reading — Monitoring time for temperature reading (0 = no monitoring) (min) .....225
10.24.44
Temperature reading — Control value for fault (0 - 255) ...........................................................226
10.24.45
Alarm functions — Frost alarm temperature for HVAC and RHCC status (°C) ..........................227
10.24.46
Alarm functions — Heat alarm temperature for RHCC status (°C) ............................................227
10.24.47
Control of additional heating stage — Temperature difference to basic stage (x 0.1°C) ............227
10.24.48
Control of additional heating stage — Additional heating type ...................................................228
10.24.49
Control of additional heating stage — P-component (x 0.1°C) ..................................................228
10.24.50
Control of additional heating stage — I-component (min) ..........................................................229
10.24.51
Cooling control — Cooling type .................................................................................................229
10.24.52
Cooling control — P-component (x 0.1°C) .................................................................................230
10.24.53
Cooling control — I-component (min.) .......................................................................................230
10.24.54
Cooling control - Extended settings ...........................................................................................230
10.24.55
Basic stage cooling ...................................................................................................................231
10.24.56
Basic stage cooling — Status object cooling .............................................................................231
10.24.57
Basic stage cooling — Mode of the control value ......................................................................231
10.24.58
Basic stage cooling — Hysteresis (x 0.1°C) ..............................................................................232
10.24.59
Basic stage cooling — Cyclic sending of the control value (min) ...............................................232
10.24.60
Basic stage cooling - PWM cycle cooling (min) .........................................................................233
10.24.61
Basic stage cooling — Maximum control value (0 - 255) ...........................................................233
10.24.62
Basic stage cooling — Minimum control value for basic load (0 to 255) ....................................233
10.24.63
Settings of basic load — Minimum control value for basic load > 0 ...........................................234
10.24.64
Basic load settings — Basic load active when controller is off ...................................................234
10.24.65
Setpoint settings — Setpoint temperature for cooling comfort (°C) ...........................................235
10.24.66
Setpoint settings — Increase for standby cooling (°C) ..............................................................235
10.24.67
Setpoint settings — Increase for ECO cooling (°C) ...................................................................235
10.24.68
Setpoint settings — Set-point temperature for heat protection (°C) ...........................................236
10.24.69
Setpoint settings — Send current setpoint ................................................................................236
10.24.70
Setpoint settings — Cyclic sending of the current set-point temperature (min) ..........................236
10.24.71
Setpoint adjustment — Maximum manual increase during cooling mode (0 - 9°C) ...................236
10.24.72
Setpoint adjustment — Maximum manual reduction during cooling mode (0 - 9°C) ..................237
10.24.73
Setpoint adjustment — Resetting of the manual adjustment for receipt of a basic setpoint .......237
10.24.74
Setpoint adjustment — Resetting the manual adjustment for change of operating mode ..........237
10.24.75
Setpoint adjustment — Resetting the manual adjustment via object .........................................238
10.24.76
Setpoint adjustment — Permanent storage of on-site operation ...............................................238
10.24.77
Setpoint adjustment — Permanent storage of on-site operation ...............................................238
10.24.78
Temperature reading — Inputs of temperature reading .............................................................238
10.24.79
Temperature reading — Inputs of weighted temperature reading .............................................239
10.24.80
Temperature reading — Weighting of internal measurement (0 to 100%) .................................239
10.24.81
Temperature reading — Weighting of external measurement (0 to 100%) ................................239
10.24.82
Temperature reading — Weighting of external measurement 2 (0 to 100%) .............................240
10.24.83
Temperature reading — Cyclic sending of the actual temperature (min) ...................................240
10.24.84
Temperature reading — Difference of value for sending the actual temperature (x 0.1°C) ........240
10.24.85
Temperature reading — Adjustment value for internal temperature measurement (x 0.1°C) ....241
10.24.86
Temperature reading — Monitoring time for temperature reading (0 = no monitoring) (min) .....242
10.24.87
Temperature reading — Control value for fault (0 - 255) ...........................................................242