KNX control elements and application parameters
Control element "Fan switch"
Product manual 2CKA00xx73xxxxx
│
139
10.8
Control element "Fan switch"
10.8.1 Name of the control element
Options: <Name>
Naming the fan switch control element, e.g. name of the fan that is to be controlled.
The length of the name is limited to 36 characters.
10.8.2 Function of the control element
Options:
Not defined (grey)
Light (yellow)
Blind (blue)
Temperature (orange)
Scene (magenta)
Alarm (red)
Feedback (green)
The parameter is used to specify the colour of the function line.
"Temperature (orange)" has been made available for functions of this type.
10.8.3 Size of the button
Options:
1 column
2 columns
The parameter is used to specify whether the control element occupies one column (one button
or control frame) or two columns (two buttons or control frames).
10.8.4 Deactivation of switch-off option
Options:
Deactivated
Activated
The parameter is used to specify whether the ventilation control can be completely switched off.