MODEM COMMUNICATION TO ABB RELAYS
Page 6 of 47
DOS OPERATING SYSTEM – PROCOMM
WINDOWS 3.1 - TERMINAL or a similar 16 bit application program commonly available.
WINDOWS 95,98, or NT – Hyperterminal or similar 32 bit application programs commonly available.
Such programs are available to be configured for handshake control, no handshake, XON/XOFF control.
A variety of cables are illustrated for connection of a device to the modem for AT terminal command
configuration, or device operation connectivity.
Knowledge of the RS232 port design is important when interconnecting a modem and an IED. Also if
configuration software is required to communicate and configure the device through the com port,
knowledge of the software’s requirement to control the RTS/CTS, CD, DSR, or DTR RS232 lines must be
known. Table 1 lists the variety of ABB products and the emulation of each of the ports and applicability
of cable design.
Table 1. Product Cable Guidelines for Connection to a Modem
Product
RS232 Port
RS232
Emulation
CTS/RTS –
DSR/DTR*
Support
Notes for Modem
Connection
DPU2000
(Front and Back Ports)
9 Pin Female
DTE
NO
NO*
Use Figure 6 Cable
DPU2000R
(Front and Back Ports)
9 Pin Female
DTE
NO
NO*
Use Figure 6 Cable
TPU2000
(Front and Back Ports)
9 Pin Female
DTE
NO
NO*
Use Figure 6 Cable
TPU2000R
(Front and Back Ports)
9 Pin Female
DTE
NO
NO*
Use Figure 6 Cable
GPU2000R
(Front and Back Ports)
9 Pin Female
DTE
NO
NO*
Use Figure 6 Cable
PONI R
9 Pin Male
DTE
YES
NO*
Use Figure 7 or 8
Cables dependent on
handshake options.
REL512 Front Port
9 Pin Female
DCE
NO
NO*
Use Figure 9 Cable
REL512 Rear Port
(Serial Port 1)
9 Pin Male
DTE
NO
NO
Use Figure 12 Cable
(Modem Handshake
options disabled).
REL512 Network Port
(DNP 3.0 Card)
9 Pin Female
DTE
YES**
NO*
Use Figures 10 or 11
Cable dependent on
handshake options.
RCP Software
IBM “XT”
25 Pin Female
IBM Compat.
9 Pin Male
Usually
DTE
Hardware
Dependent
NO
NO*
Sample cables are
illustrated in Figures 12
and 13.
ECP Software
Or
WinECP Software
IBM “XT”
25 Pin Female
IBM Compat.
9 Pin Male
Usually
DTE
Hardware
Dependent
NO
NO*
Sample cables are
illustrated in Figures 12
and 13.
PONI M COMSET
Software
IBM “XT”
25 Pin Female
IBM Compat.
9 Pin Male
Usually
DTE
Hardware
Dependent
YES
NO*
Sample cables are
illustrated in Figures 12
and 13.
** PONI – R Card does not support DTR/DSR HANDSHAKE LINES
Summary of Contents for REL 356
Page 23: ...ABB REL 356 Current Differential Protection 1 10 Product Overview and Specifications ...
Page 83: ...ABB REL 356 Current Differential Protection 3 36 Settings and Application ...
Page 127: ...ABB REL 356 Current Differential Protection 5 28 Testing ...
Page 186: ...LINE SECTIONALIZING USING A PLC AND ABB PROTECTIVE RELAY Page 49 of 53 ...
Page 187: ...LINE SECTIONALIZING USING A PLC AND ABB PROTECTIVE RELAY Page 50 of 53 ...
Page 188: ...LINE SECTIONALIZING USING A PLC AND ABB PROTECTIVE RELAY Page 51 of 53 ...
Page 189: ...LINE SECTIONALIZING USING A PLC AND ABB PROTECTIVE RELAY Page 52 of 53 ...