After calibration
Note
Action
xx1600002102
Check the o-ring on the fixed calibration pin.
Replace if damaged or missing.
1
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
2
Protection cover and plug set: .
3HAC064875-001 (axes 1, 2, 3 and
4)
3HAC059487-001 (axes 5 and 6)
xx1500000952
Reinstall the protective plug and sealing in the
bushing on each axis, directly after the axis has
been calibrated. Ensure that the sealing is not
damaged.
Replace the plug and the sealing with new spare
part, if missing or damaged.
3
Protection cover and plug set: .
3HAC064875-001 (axes 1, 2, 3 and
4)
3HAC059487-001 (axes 5 and 6)
Product manual - IRB 6720
603
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.4.4 Axis Calibration - Running the calibration procedure
Continued