Note
Action
xx1400000372
Foundry Plus
:
Apply Mercasol in the hole for the locking
screw.
2
User instructions are enclosed with the
tool.
Restore the balancing device according to
instructions for the press equipment.
3
xx0900000813
Go to the user instructions enclosed with
the press tool.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
Hex socket head cap screw: M10x25 8.8-
A3F.
Apply flange sealant and refit the cover
plate on the back of the balancing device.
4
Tightening torque: 50 Nm.
Flange sealant for conical fittings: Loctite
5400 (or equivalent Loctite 577).
xx2200001330
Continues on next page
210
Product manual - IRB 6720
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the balancing device
Continued