Note
Action
Hex socket head cap screw: M10x30 12.9
Gleitmo 603+Geomet 500 (4 pcs)
Secure the motor with its attachment
screws and washers.
8
Tightening torque: 24 Nm.
xx2100002204
See
Performing a leak-down test on
Perform a leak-down test.
9
Disconnect the brake release tool.
10
Connecting the axis-5 motor cables
Note
Action
Put the motor cables in place in the open-
ing.
1
Torx pan head screw: M3x12 Stainless
steel A2-70
Refit the cable bracket with the screws.
2
xx2200001735
Continues on next page
416
Product manual - IRB 6720
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.7.5 Replacing the axis-5 motor
Continued