Note
Action
xx2200001734
Disconnect the signal cable connector.
4
xx2200001733
Disconnect the power cable connector by
removing the attachment screw.
5
xx2200001735
Remove the cable bracket by removing the
screws.
6
Remove the motor cables.
7
Disconnecting the axis-3 and axis-4 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
548
Product manual - IRB 6730
3HAC085699-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.3 Replacing the axis-3 gearbox
Continued