Note
Action
xx2100001192
First push down the tool by hand to guide
down the sealing aligned.
5
Then use a rubber mallet to knock down
the tool and sealing evenly, until the sealing
has reached the bottom all the way around.
Remove the mounting tool.
6
xx2100001193
Verify that the cassette sealing is fitted
evenly by measuring the distance (A)
between the sealing and the axis-1 tube
upper edge, at four (4) locations. The
measurement is approximately 9 mm.
7
Rust preventive: 3HAC034903-001 (Mer-
casol 3110 Waxcoat. Recommended drying
time is 24h.)
Protection type Foundry Plus
Apply rust preventive to the outer surface
of the gearbox tube and outer surface of
the frame hole, all the way down to the
cassette sealing, as shown in the figure.
8
xx2100001170
xx2100001172
Continues on next page
482
Product manual - IRB 6730
3HAC085699-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.1 Replacing the axis-1 gearbox
Continued