![ABB IRB 6730 Product Manual Download Page 458](http://html1.mh-extra.com/html/abb/irb-6730/irb-6730_product-manual_3670664458.webp)
Note
Action
xx2200001398
Hold the mechanical stop pin in a firm grip,
and remove it by unscrewing the set screw.
3
xx2200001430
Foundry Plus
Remove the axis-1 cable protection plate by
removing the attachment screws.
4
See
Floor-mounted robot: Draining the
Begin draining the axis-1 gearbox.
Note
There will be some oil left in the gear after
draining.
5
Disconnecting the axis-1 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Remove the motor cover by removing the
screws.
2
Continues on next page
458
Product manual - IRB 6730
3HAC085699-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.1 Replacing the axis-1 gearbox
Continued