Note
Action
xx2100002709
If DressPack is installed:
Open the ball joint housing on the arm tube
and remove the DressPack cable package.
3
xx2000000373
Remove the wrist cover.
4
Disconnecting the axis-6 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx2200001434
Unscrew the attachment screws and re-
move the motor cover.
2
Continues on next page
312
Product manual - IRB 6730
3HAC085699-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.7.1 Removing the cable harness
Continued