Note
Action
Make sure that all lifting accessories still
is fitted correctly on the arm system.
2
Lift the arm system up to reach the contact
surfaces underneath the frame.
3
Wipe clean the contact surfaces from any
remaining contamination.
4
xx2200001419
Lift the arm system to mounting position,
and verify that the hole pattern match and
that the guide pins will enter the correct
holes in the frame.
Note
Also check that the guiding pin in the
gearbox is aligned with the pin hole in the
frame.
xx2300000013
5
Lower the arm system to align the longest
guide pin into the hole.
6
xx2200001420
Lower the arm system to align the other
guide pin into the hole.
7
Continues on next page
Product manual - IRB 6730
477
3HAC085699-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.9.1 Replacing the axis-1 gearbox
Continued