ABB i-bus
®
KNX
Group objects
FCC/S 1.X.X.1 | 2CDC 508 200 D0211 Rev A 320
No.
Function
Name
Data Point Type
(DPT)
Length
Flags
C
R
W T
U
70
Status Control value Basic-stage heating
Channel – Controller 1.001
1 bit
X
X
X
71
Status Control value Additional-stage heating
Channel – Controller 5.001
1 byte
X
X
X
71
Status Control value Additional-stage heating
Channel – Controller 1.001
1 bit
X
X
X
72
Status Control value Basic-stage cooling
Channel – Controller 5.001
1 byte
X
X
X
72
Status Control value Basic-stage cooling
Channel – Controller 1.001
1 bit
X
X
X
73
Status Control value Additional-stage cooling
Channel – Controller 5.001
1 byte
X
X
X
73
Status Control value Additional-stage cooling
Channel – Controller 1.001
1 bit
X
X
X
74
Not assigned
75
Actual temperature
Channel – Controller 9.001
2 bytes
X
X
X
76
External temperature 1
Channel – Controller 9.001
2 bytes
X
X
77
External temperature 2
Channel – Controller 9.001
2 bytes
X
X
78
Fault: actual temperature (master)
Channel – Controller 1.002
1 bit
X
X
X
79
Current setpoint
Channel – Controller 9.001
2 bytes
X
X
X
80
Operating mode normal (master)
Channel – Controller 20.102
1 byte
X
X
X
X
81
Operating mode override (master)
Channel – Controller 20.102
1 byte
X
X
X
X
82
Window contact (master/slave)
Channel – Controller 1.019
1 bit
X
X
83
Presence detector (master/slave)
Channel – Controller 1.018
1 bit
X
X
84
Status Heating
Channel – Controller 1.001
1 bit
X
X
X
85
Status Cooling
Channel – Controller 1.001
1 bit
X
X
X
86
Activate minimum control value (basic load)
Channel – Controller 1.003
1 bit
X
X
87
Heating/Cooling changeover
Channel – Actuator
1.100
1 bit
X
X
X
X
87
Heating/Cooling changeover
Channel – Controller 1.100
1 bit
X
X
X
X
88
Base setpoint
Channel – Controller 9.001
2 bytes
X
X
89
Reset manual setpoint adjustment
Channel – Controller 1.017
1 bit
X
X
90
Dew point alarm
Channel – Controller 1.005
1 bit
X
X
91
Fill level alarm
Channel – Controller 1.005
1 bit
X
X
92
Outside temperature for summer compensation Channel – Controller 9.001
2 bytes
X
X
93
Summer compensation active/inactive
Channel – Controller 1.002
1 bit
X
X
X
94
Setpoint reached
Channel – Controller 1.002
1 bit
X
X
X
95
Request On/Off (master)
Channel – Controller 1.001
1 bit
X
X
96
Confirm On/Off (master)
Channel – Controller 1.001
1 bit
X
X
97
Setpoint display (master)
Channel – Controller 9.002
2 bytes
X
X
X
98
Request setpoint adjustment
Channel – Controller 9.001
2 bytes
X
X
98
Request setpoint adjustment
Channel – Controller 9.002
2 bytes
X
X
98
Request setpoint adjustment
Channel – Controller 6.010
1 byte
X
X
98
Request setpoint adjustment
Channel – Actuator
9.001
2 bytes
X
X
98
Request setpoint adjustment
Channel – Actuator
9.002
2 bytes
X
X
98
Request setpoint adjustment
Channel – Actuator
6.010
1 byte
X
X
99
Confirm setpoint (master)
Channel – Controller 9.001
2 bytes
X
X
X
99
Confirm setpoint (master)
Channel – Controller 9.002
2 bytes
X
X
X
99
Confirm setpoint (master)
Channel – Controller 6.010
1 byte
X
X
X
100
Request heating/cooling (master)
Channel – Controller 1.100
1 bit
X
X