Communication protocol 99
Basic speed control plus drive parameters
assembly
The Basic speed control plus drive parameters assembly, defined
by ABB, adds configurable drive parameters to the Basic speed
control assembly of the ODVA AC/DC drive profile.
The format of the output assembly is:
Instance 120
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Fault
Reset
Run
Fwd
1
2
Speed Reference (Low Byte)
3
Speed Reference (High Byte)
4
DATA OUT 1 Value (Low Byte)
5
DATA OUT 1 Value (High Byte)
6
DATA OUT 2 Value (Low Byte)
7
DATA OUT 2 Value (High Byte)
8
DATA OUT 3 Value (Low Byte)
9
DATA OUT 3 Value (High Byte)
10
DATA OUT 4 Value (Low Byte)
11
DATA OUT 4 Value (High Byte)
12
DATA OUT 5 Value (Low Byte)
13
DATA OUT 5 Value (High Byte)
14
DATA OUT 6 Value (Low Byte)
15
DATA OUT 6 Value (High Byte)
16
DATA OUT 7 Value (Low Byte)
17
DATA OUT 7 Value (High Byte)
18
DATA OUT 8 Value (Low Byte)
19
DATA OUT 8 Value (High Byte)
20
DATA OUT 9 Value (Low Byte)