1-7
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section take effect on all Ethernet ports automatically.
Configuring Errored Frame Event Detection
An errored frame event occurs when the number of detected error frames over a specific interval
exceeds the predefined threshold.
Follow these steps to configure errored frame event detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the errored frame
event detection interval
oam errored-frame period
period-value
Optional
1 second by default
Configure the errored frame
event triggering threshold
oam errored-frame threshold
threshold-value
Optional
1 by default
Configuring Errored Frame Period Event Detection
An errored frame period event occurs if the number of frame errors in specific number of received
frames exceeds the predefined threshold.
Follow these steps to configure errored frame period event detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the errored frame
period event detection period
oam errored-frame-period
period period-value
Optional
1000 milliseconds by default
Configure the errored frame
period event triggering
threshold
oam errored-frame-period
threshold threshold-value
Optional
1 by default
Configuring Errored Frame Seconds Event Detection
An errored frame seconds event occurs when the number of error frame seconds detected on a port
over a detection interval exceeds the error threshold.
Follow these steps to configure errored frame seconds event detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the errored frame
seconds event detection
interval
oam errored-frame-seconds
period period-value
Optional
60 second by default
Summary of Contents for S7902E
Page 82: ...1 4 DeviceA interface tunnel 1 DeviceA Tunnel1 service loopback group 1 ...
Page 200: ...1 11 DeviceB display vlan dynamic No dynamic vlans exist ...
Page 598: ...ii ...
Page 1757: ...4 9 ...
Page 1770: ...6 4 ...
Page 2017: ...2 11 Figure 2 3 SFTP client interface ...
Page 2238: ...1 16 DeviceA cfd linktrace service instance 1 mep 1001 target mep 4002 ...