User’s Manual 1PH HYD3000-HYD6000-ZP1
Rev. 1.0 01/09/2023
Identification: MD-AL-GI-00
Rev. 1.1 of 27/01/2023 - Application: GID
107/193
5) If PV prod battery < LOAD
consumption, the missing energy to feed the
loads will be imported from the grid.
6) Press “DOWN” to display the current
grid/battery parameters, press “UP” to go back to
the main interface.
2) Time-of-ues Mode
You can set dates, days and times in which to set a forced charging of batteries up to the % of SOC set. Outside
the non-peak charging period, the inverter operates in automatic mode.
You can set multiple Time-of-use rules to meet your more complex requirement. Right now we support 4
rules maximum (rule 0/1/2/3).
2.Time-of-use
Mode
Time-of-use Mode
Rules. 0: Disabled
From
To
SOC
Charge
02h00m - 04h00m
070%
01000W
Effective
Date
Dec. 22
-
Mar. 21
Weekday select
Mon. Tue. Wed. Thu. Fri. Sat. Sun.