![ZCS AZZURRO 1PH HYD3000-ZP1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/zcs/azzurro-1ph-hyd3000-zp1/azzurro-1ph-hyd3000-zp1_user-manual_4421074019.webp)
User’s Manual 1PH HYD3000-HYD6000-ZP1
Rev. 1.0 01/09/2023
Identification: MD-AL-GI-00
Rev. 1.1 of 27/01/2023 - Application: GID
18/193
2.2.
Assembly and maintenance diagram
•
The battery must be protected against short circuits during transport and installation.
•
The inverter 1PH HYD3000-HYD6000-ZP1/batteries must be located in well-ventilated areas. Do not place
the 1PH HYD3000-HYD6000-ZP1 inverter/batteries in a cabinet or in an airtight or poorly ventilated
location. This could be extremely hazardous to the performance and life of the system.
•
Keep the 1PH HYD3000-HYD6000-ZP1 inverter and batteries away from direct sunlight. Do not bring the
1PH HYD3000-HYD6000-ZP1 inverter and batteries near ovens, flames or other heat sources as the battery
may catch fire and cause an explosion.
•
Use a multimeter to check the battery polarity and voltage before turning on the power. Make sure that the
connections are made according to the instructions in this manual.
•
Use the multimeter to check the PV voltage and polarity before closing the PV switch. Make sure that the
connections are made according to the instructions in this manual.
•
If you want to store the batteries without using them, disconnect them from the 1PH HYD3000-HYD6000-
ZP1 inverter and store them in a cool, dry and well-ventilated area.
•
Battery maintenance workers must have the skills and knowledge required to carry out this activity.
•
The 1PH HYD3000-HYD6000-ZP1 inverter does not have an isolation transformer so the positive and
negative polarities of the PV string do NOT have to be grounded, otherwise the inverter may be damaged.
All non-current-carrying metal parts (such as the PV module frame, PV rack, housing of the combiner box,
and housing of the inverter) in the photovoltaic power system must be connected to the ground.
•
Attention: Do not disassemble or break the battery. The electrolytes in the battery may be toxic and cause
damage to skin and eyes.
•
Attention: during installation and maintenance of the product, please follow the rules below.
a)
Remove watches, rings and other metal objects.
b)
Only use tools with insulated handles.
c)
Wear rubber gloves and shoes.
d)
Do not place tools or metal objects on top of the battery.
e)
Turn off the 1PH HYD3000-HYD6000-ZP1 inverter and batteries before connecting/disconnecting
the battery terminals.
f)
Both the positive and negative polarities must be isolated from the ground.
•
Please install the product according to the following section. Place inverter in an appropriate bearing
capacity objects (such as solid brick wall, or strength equivalent mounting surface, etc.) and make sure
inverter vertical placed. A proper installation location must have enough space for fire engine access in
order for maintenance if faulty occur. Ensure the inverter is installed in a wall ventilated environment and
have enough air cooling cycle. Air humidity should less than 90%.