3) Timing Mode
Changing the value of a rule can set multiple timing rules.
3.Timing Mode
Timing Mode
Rules. 0:
Enabled/Disabled
Charge Start
22 h 00
m
Charge End
05 h 00
m
Charge Power
02000
W
DisCharge
Start
14 h
00m
DisCharge End
16 h
00m
DisCharge
Power
02500
W
4) Passive Mode
4.Passive Mode
Passive mode allows the inverter to see the batteries but not let them intervene neither in charge nor in
download. This setting is useful at the level of initial tests on the inverter for more detailed information
regarding passive operation, ask Zucchetti Centro Sistemi S.p.A.
10.5.5.
Photovoltaic Input Mode
Photovoltaic Input Mode selection: The 1PH HYD3000-HYD6000-ZP1 inverter has two MPPT channels. The two
MPPTs can operate both independently and in parallel. If the PV strings are connected in parallel, “parallel mode”
must be selected before connecting to the inverter; otherwise the default configuration (independent mode) must
be used.
After changing the PV input mode, restart the 1PH HYD3000-HYD6000-ZP1 inverter to validate this change.
10.5.6.
EPS Mode
The EPS mode allows enabling the EPS output for critical loads.
5. Select EPS mode
1. EPS control mode
1. Enable EPS mode
1. Disable EPS mode