For the 1PH HYD3000-HYD6000-ZP1-single-phase hybrid inverter, use only one positive and one negative of
those shown in the figure below.
Figure 106d
– Connecting the serial line via the communication connector for 1PH HYD3000-HYD6000-HP
c.
Position the dip switches of the last inverter of the daisy chain as shown in the figure below
for activating the 120 Ohm resistor and closing the communication chain. If there are no
switches, physically connect a 120 Ohm resistor to terminate the bus.
Figure 107
– Positioning of dip switches to connect the isolation resistor
6)
Check that the RS485 icon is shown on the display of all the inverters. This indicates that the inverters
are actually connected via the serial line. If this symbol does not appear, check that the connection is
correct, as indicated in this guide.