11-13
IM 253710-01E
Waveform Analysis
11
When [Horizontal] is Selected
Selecting the waveform on which to place the H cursor
4.
Press the [Cursor1 Trace] soft key to display the box used to select the
waveform on which to place the H cursor.
5.
Turn the jog shuttle to select the waveform from [CH1] to [Math2].
6.
Press the SELECT key to confirm the selection.
Moving the H cursor
• Moving H cursor 1
7.
Press the [Cursor1 = / Cursor2 =] soft key to set the jog shuttle control to
[Cursor1 =].
8.
Turn the jog shuttle to move H cursor 1.
• Moving H cursor 2
9.
Press the [Cursor1 = / Cursor2 =] soft key to set the jog shuttle control to
[Cursor2 =].
10.
Turn the jog shuttle to move H cursor 2.
• Moving H cursor 1 and 2 simultaneously
11.
Press the [Cursor1 = / Cursor2 =] soft key to set the jog shuttle control to both
[Cursor1 =] and [Cursor2 =].
12.
Turn the jog shuttle to move H cursor 1 and 2 simultaneously. The distance
between them is kept constant.
11.4 Measuring with the Cursor