8-17
IM 253710-01E
Numerical Display
8
• Single List
• When the display format is [Numeric], 48 items of numerical data of one type of
measurement function are displayed in two columns.
• When the display format is other than [Numeric], 22 items of numerical data of
one type of measurement function are displayed in two columns.
• Dual List
• When the display format is [Numeric], 24 items of numerical data of two types of
measurement functions are displayed in each column.
• When the display format is other than [Numeric], 11 items of numerical data of
two types of measurement functions are displayed in each column.
•
Σ
List
• A table indicating the numerical data for each measurement item is displayed.
The measurement functions U, I, P, S, Q,
λ
,
φ
, and so on are displayed vertically
and symbols representing the elements and wiring methods are displayed
horizontally.
• The sixth horizontal item (
Σ
B) is hidden behind the menu. You can view the
hidden data by clearing the menu by pressing the ESC key.
Resetting the order of the displayed items
If the number of displayed items is set to [8] or [16], the order of the displayed items
can be reset to a preset order. For details regarding the reset information, see
Appendix 4, “List of Initial Settings and Display Order of Numerical Data.”
Scrolling the display
Because all the data cannot fit on one screen, a scroll function is provided.
• When the number of displayed items is set to [8] or [16]
Turn the jog shuttle to move the highlight to another measurement function. The
menu items that are displayed change as follows.
• Harm Item No.
The data number of the highlighted measurement function is displayed.
• Function
The symbol representing the highlighted measurement function is displayed.
When [None] is displayed, an item without a selected measurement function is
being specified using the jog shuttle. In this case, the area for displaying the
measurement function and data displays [-------] (no data).
• Element
The element/wiring method of the highlighted measurement function is
displayed.
• Order
The harmonic order of the highlighted measurement function is displayed (Total
or dc (0th order) up to 500th order).
• When [Single List] or [Dual List] is selected
Total or dc (0th order) up to 500th order is displayed in the [order] section of the
Display setting menu. When the selected measurement function is U, I, or P, the
harmonic distortion factor, Uhdf, Ihdf, or Phdf is displayed, respectively. When the
measurement function is some function other than U, I, or P, [-------] (no data) is
displayed in place where the harmonic distortion factor is to be displayed.
8.4 Displaying Harmonic Measurement Data