5-16
IM CW240E
AUTO
When AUTO is selected, the position of the decimal point and the unit of
measurement change as follows:
The maximum number of digits that can be displayed for integrated electric
energy is 999999 (6 digits). If electric energy is added to make it 1000000 (7
digits), the position of the decimal point will be moved automatically (the unit of
measurement also changes automatically).
Example:
9.99999 mWh
→
10.0000 mWh
99.9999 Wh
→
100.000 Wh
999.999 mWh
→
1.00000 Wh
999.999 Wh
→
1.00000 kWh
The start value for integration has been specified as shown below according to
the rated power value.
Table 2
Rated power
⫻
VT ratio
⫻
CT ratio
1.5 to 9.999 mW
10 to 99.99 mW
100 to 999.9 mW
1 to 9.999 W
10 to 99.99 W
100 to 999.9 W
1 to 9.999 kW
10 to 99.99 kW
100 to 999.9 kW
1 to 9.999 MW
10 to 99.99 MW
100 to 999.9 MW
1 to 9.999 GW
10 to 99.99 GW
100 to 999.9 GW
1 to 9.999 TW
10 to 99.99 TW
100 to 999.9 TW
0.00000 to mWh
0.0000 to mWh
0.000 to mWh
0.00000 to Wh
0.0000 to Wh
0.000 to Wh
0.00000 to kWh
0.0000 to kWh
0.000 to kWh
0.00000 to MWh
0.0000 to MWh
0.000 to MWh
0.00000 to GWh
0.0000 to GWh
0.000 to GWh
0.00 to GWh
0.0 to GWh
0 to GWh
Start value for integration of electric energy
TIP
If an integrated value exceeds the maximum displayable integrated value (999999
GWh), the reading will be reset to an integration start value (zero), letting integration
continue.
5.3 Ranges and Number of Digits