5-6
IM CW240E
5.3
Ranges and Number of Digits
This section describes the voltage, current, power, and electric energy ranges.
●
Voltage Ranges
150/300/600/1000 V
●
Current Ranges
Current ranges vary depending on the clamp-on probe to be used.
Clamp-on Probe
96036
200mA
500mA
1A
2A
96033 5A
10A
20A
50A
96030
20A 50A 100A
200A
96031 50A
100A
200A
500A
96032
200A 500A 1000A
96034_1
300A 750A 1500A
3000A
96034_2
200A 500A 1000A
2000A
96034_3
100A 200A 500A 1000A
96035_1
300A 750A 1500A
3000A
96035_2
30A 75A 150A
300A
96034 or 96035: Current range is selected using the switch on a clamp-on probe.
Current Range
●
Active and Reactive Power Ranges
The active and reactive power ranges are determined as shown below
depending on the voltage range, current range, and/or wiring system (wiring).
Wiring System (Wiring)
1P2W
1P3W
1P3W3I
3P3W2I
3P3W3I
3P3W+1P3W*
3P4W
3P4W4I
*: Scott connection
Power Range
Voltage range
⫻
current range
Voltage range
⫻
current range
⫻
2
Voltage range
⫻
current range
⫻
3