![YOKOGAWA av550g Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/yokogawa/av550g/av550g_user-manual_911433029.webp)
< 2. Specifications >
2-12
IM 11M12D01-01E
Safety and EMC conforming standards
Safety: Conforms to EN 61010-1, CAN/CSA-C22.2 No. 61010.1 certified,
UL Std. No. 61010-1 certified
EMC: Conforms to EN 61326-1 Class A, Table 2 *,
EN 61326-2-3, EN 61000-3-2, EN 61000-3-3
* : Influence of immunity environment (Criteria A ) : ±12.5% of F. S.
CE (Only HART communication type)
EMC Regulatory Arrangement in Australia and New Zealand (RCM)
EN61326-1 Class A
Korea Electromagnetic Conformity Standard Class A
RoHS: EN 50581
CAUTION
This instrument is a Class A product, and it is designed for use in the industrial environment. Please
use this instrument in the industrial environment only.
Maximum Distance between Probe and Converter: Conductor two-way resistance must be 10 Ω or
less (when a 1.25 mm
2
cable or equivalent is used, 300 m or less)
Construction:
Indoor installation
Wiring Connection:
Number of wire holes 30 pieces
Wire hole size: Ø17 mm for grommet, Ø6 to Ø12 mm for cable gland (option).
Installation:
Wall mounting
Case:
Aluminum alloy (100 V type), Steel plate and Aluminum alloy (200 V type)
Paint Color:
Silver Gray (Munsell 3.2PB7.4/1.2)
Finish:
Polyurethane corrosion-resistance coating
Weight:
Approx. 13 kg (100 V type), Approx. 25 kg (200 V type)
2.4.2 Functions
Display Functions:
Value Display;
Displays values of the measured oxygen concentration, etc
Graph Display;
Displays trends of measured oxygen concentration
Data Display;
Displays various useful data for maintenance, such as cell
temperature, reference junction temperature, maximum/minimum
oxygen concentration, or the like.
Status Message;
Indicates an alarm or error occurrence with flashing of the
corresponding icon. Indicates status such as warming-up,
calibrating, or the like by icon.
Alarm, Error Display;
Displays alarms such as “Abnormal cell e.m.f.” when any such
status occurs.
Calibration functions:
Auto-Calibration;
It calibrates automatically at specified intervals.
Semi-auto Calibration; Input calibration direction on the touch screen or contact, then it
calibrates automatically afterwards.
Manual Calibration;
Calibration with opening/closing the valve of calibration gas in
operation interactively with an LCD touch screen.