<8. Detailed Data Setting>
8-19
IM 11M12D01-01E
<Setting Procedure>
1) Touch the Setup key on the basic panel display, and the [Execution/Setup] display appears.
2) Select [Commissioning] and the Commissioning display appears.
3) Select [Others] then [Fuel setup] and the display of Figure 8.21 appears.
4) Select [Content of moisture in exhaust gas] and [Theoretical air quantity required] in turn and
enter numeric data.
5) Select [more] and touch the Enter key, and a display like Figure 8.22 is displayed. Here enter
[Value of the X coefficient] and [Absolute humidity of the atmosphere] then select [finished] to
revert to the display of Figure 8.21.
Enter
Fuel setup
F8-21E.ai
Theoretical air quantity
required: 1. 0 0 m3/kg
more. . . . . .
Contents of moisture in
exhaust gas: 0. 0 0 m3/kg
Enter
Fuel setup
F8-22E.ai
Absolute humidity of the
atmosphere:
0. 0 0 0 0 kg/kg
finished.
Value of the X coefficient:
1. 0 0
See Manual for details
!
Figure 8.21 “Fuel Setup” display 1
Figure 8.22 “Fuel Setup” display 2
< Default setting>
Fuel parameters are set to defaults in Table 8.8 prior factory shipment or after data initialization.
Table 8.8 Default values of “Fuel” settings
Item
Default
Amount of water vapor in exhaust gas
0.00 m
3
/kg (m
3
)
Theoretical amount of air
1.00 m
3
/kg (m
3
)
X value
1.00
Absolute humidity of the atmosphere
0.0 kg/kg