17.1 List of Parameters
17.1.2 List of Parameters
17-27
17
Parameter and Object Lists
Pn515
(2515h)
2
Input Signal Selections
6
0000h to
FFFFh
–
8888h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
/DBANS (Dynamic Brake Answer Input) Signal Allocation
0
Detect DB circuit error when CN1-13 input signal is ON (closed) while /DBON
signal is ON.
1
Detect DB circuit error when CN1-7 input signal is ON (closed) while /DBON
signal is ON.
2
Detect DB circuit error when CN1-8 input signal is ON (closed) while /DBON
signal is ON.
3
Detect DB circuit error when CN1-9 input signal is ON (closed) while /DBON
signal is ON.
4
Detect DB circuit error when CN1-10 input signal is ON (closed) while /DBON
signal is ON.
5
Detect DB circuit error when CN1-11 input signal is ON (closed) while /DBON
signal is ON.
6
Detect DB circuit error when CN1-12 input signal is ON (closed) while /DBON
signal is ON.
7
Disable DB circuit error detection using the /DBANS signal.
8
Disable DB circuit error detection using the /DBANS signal.
9
Detect DB circuit error when CN1-13 input signal is OFF (open) while /DBON
signal is ON.
A
Detect DB circuit error when CN1-7 input signal is OFF (open) while /DBON
signal is ON.
B
Detect DB circuit error when CN1-8 input signal is OFF (open) while /DBON
signal is ON.
C
Detect DB circuit error when CN1-9 input signal is OFF (open) while /DBON
signal is ON.
D
Detect DB circuit error when CN1-10 input signal is OFF (open) while /DBON
signal is ON.
E
Detect DB circuit error when CN1-11 input signal is OFF (open) while /DBON
signal is ON.
F
Detect DB circuit error when CN1-12 input signal is OFF (open) while /DBON
signal is ON.
n.X
Reserved parameter (Do not change.)