17.1 List of Parameters
17.1.2 List of Parameters
17-8
Pn00A
(200Ah)
2
Application Function
Selections A
0000h to
0044h
–
0001h
All
After
restart
Setup
–
Pn00B
(200Bh)
2
Application Function
Selections B
0000h to
1121h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Motor Stopping Method for Group 2 Alarms
Reference
0
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 (2001h) = n.
X).
1
Decelerate the motor to a stop using the torque set in Pn406
(2406h) as the maximum torque. Use the setting of Pn001 (2001h)
= n.
X for the status after stopping.
2
Decelerate the motor to a stop using the torque set in Pn406
(2406h) as the maximum torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in
Pn30A (230Ah). Use the setting of Pn001 (2001h) = n.
X for
the status after stopping.
4
Decelerate the motor to a stop using the deceleration time set in
Pn30A (230Ah) and then let the motor coast.
n.
X
Stopping Method for Forced Stops
Reference
0
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 (2001h) = n.
X).
1
Decelerate the motor to a stop using the torque set in Pn406
(2406h) as the maximum torque. Use the setting of Pn001 (2001h)
= n.
X for the status after stopping.
2
Decelerate the motor to a stop using the torque set in Pn406
(2406h) as the maximum torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in
Pn30A (230Ah). Use the setting of Pn001 (2001h) = n.
X for
the status after stopping.
4
Decelerate the motor to a stop using the deceleration time set in
Pn30A (230Ah) and then let the motor coast.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Operator Parameter Display Selection
Reference
0
Display only setup parameters.
1
Display all parameters.
n.
X
Motor Stopping Method for Group 2 Alarms
Reference
0
Stop the motor by setting the speed reference to 0.
1
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 (2001h) = n.
X).
2
Set the stopping method with Pn00A (200Ah) = n.
X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)