17.1 List of Parameters
17.1.2 List of Parameters
17-26
Pn512
(2512h)
2
Output Signal Inverse
Settings 1
0000h to
1111h
–
0000h
All
After
restart
Setup
Pn513
(2513h)
2
Output Signal Inverse
Settings 2
0000h to
0011h
–
0000h
All
After
restart
Setup
Pn514
(2514h)
2
Output Signal Selec-
tions 4
0000h to
0666h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Output Signal Inversion for CN1-1 and CN1-2 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-23 and CN1-24 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-25 and CN1-26 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.X
Output Signal Inversion for CN1-27 and CN1-28 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-29 and CN1-30 Terminals
Reference
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
/PM (Preventative Maintenance Output) Signal Allocation
Reference
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4
Output the signal from the CN1-27 or CN1-28 output terminal.
5
Output the signal from the CN1-29 or CN1-30 output terminal.
6
Reserved setting (Do not use.)
n.X
Reserved parameter (Do not change.)