6.11 Holding Brake
6.11.5 Built-in Brake Relay Usage Selection
6-36
•
When the Time Set In Pn508 Elapses after the Power Supply to the Motor Is Stopped
6.11.5
Built-in Brake Relay Usage Selection
SERVOPACKs with built-in brake control contain a brake relay.
Set Pn023 = n.
X (Built-in Brake Relay Usage Selection) to specify whether to use the built-in
brake relays.
The Servomotor will be limited to its maximum speed even if the brake reference output speed
level (Rotary Servomotor: Pn507, Linear Servomotor: Pn583) is higher than the maximum speed.
Pn508
Enable
Operation
Disable
Operation
Linear Servomotor: Pn583
Rotary Servomotor: Pn507
Motor stopped with dynamic
brake or by coasting
(Pn001 = n.
X)
Power
supplied.
Power not
supplied.
OFF (Brake applied.)
Motor speed
Motor power status
/BK signal
Controlword
(6040h), alarm,
or power OFF
ON (Brake released.)
Important
Parameter
Description
When Enabled
Classification
Pn023
(2023h)
n.
0
(default setting)
Use the built-in brake relays.
After restart
Setup
n.
1
Do not use the built-in brake relays.