8.6 Convenient Function to Use during Trial Operation
8.6.3 Test without a Motor
8-23
8
T
rial Operation and Actual Operation
Restrictions
The following functions cannot be used during the test without a motor.
•
Regeneration and dynamic brake operation
•
Brake output signal
Refer to the following section for information on confirming the brake output signal.
•
Items marked with “
×
” in the following utility function table
S
Digital Operator
Executable?
Reference
Button in
Menu
Dialog Box
S Function
Name
Fn No.
Utility Function Name
Motor Not
Connected
Motor
Connected
Setup
Origin Search
Fn003
Origin Search
Absolute Encoder
Reset
Fn008
Reset Absolute
Encoder
×
Analog Monitor Out-
put Adjustment
Fn00C
Adjust Analog Monitor
Output Offset
Fn00D
Adjust Analog Monitor
Output Gain
Motor Current Detec-
tion Offset Adjust-
ment
Fn00E
Autotune Motor Cur-
rent Detection Signal
Offset
×
Fn00F
Manually Adjust Motor
Current Detection Sig-
nal Offset
×
Parameter Write Pro-
hibition Setting
Fn010
Write Prohibition Set-
ting
Multiturn Limit Setting
Fn013
Multiturn Limit Setting
after Multiturn Limit
Disagreement Alarm
×
Reset Configuration
Error of Option Mod-
ule
Fn014
Reset Option Module
Configuration Error
Initializing the Vibra-
tion Detection Level
Fn01B
Initialize Vibration
Detection Level
×
×
Set Origin
Fn020
Set Absolute Linear
Encoder Origin
×
Reset Motor Type
Alarm
Fn021
Reset Motor Type
Alarm
−
Software Reset
Fn030
Software Reset
Polarity Detection
Fn080
Polarity Detection
×
×
Tuning-less Level
Setting
Fn200
Tuning-less Level Set-
ting
×
×
Easy FFT
Fn206
Easy FFT
×
×
Parameter
Initialize
*
Fn005
Initialize Parameters
Tuning
Autotuning without
Host Reference
Fn201
Advanced Autotuning
without Reference
×
×
Autotuning with Host
Reference
Fn202
Advanced Autotuning
with Reference
×
×
Custom Tuning
Fn203
One-Parameter Tuning
×
×
Adjust Anti-reso-
nance Control
Fn204
Adjust Anti-resonance
Control
×
×
Vibration Suppres-
sion
Fn205
Vibration Suppression
×
×
Continued on next page.