5.3 SERVOPACK Models without a Built-In Dynamic Brake
5.3.1 Using the Dynamic Brake
5-11
5
W
iring and Settings for the Dynamic Brake
Setting When Not Using Dynamic Braking
When not using dynamic braking, set Pn001 = n.
X (Motor Stopping Method for Servo
OFF and Group 1 Alarms) to 2.
The A.042 (Parameter Combination Error) alarm will be reset when you set Pn001 = n.
2
(Coast to a stop) and turn the power supply OFF and ON again.
Setting When Using Dynamic Braking
When using dynamic braking, set Pn001 = n.
X (Motor Stopping Method for Servo OFF
and Group 1 Alarms) to 0 or 1.
You must also create the dynamic brake circuit in order to perform dynamic braking. The A.042
(Parameter Combination Error) alarm will be reset when you turn the power supply OFF and ON
again after the parameters for the dynamic brake circuit and stopping the Servomotor have
been set.
You must complete the following items to use the dynamic brake.
•
Selecting the Dynamic Brake Resistor
5.3.2 Selecting the Devices Required for the Dynamic Brake Circuit
•
Creating the Dynamic Brake Circuit
5.3.3 Wiring the Dynamic Brake Circuit
•
Parameter Settings for the Dynamic Brake
5.3.4 Parameter Settings for the Dynamic Brake Circuit
Parameter
Meaning
When Enabled
Classification
Pn001
(2001h)
n.
0
(default setting)
Stop the motor by applying the
dynamic brake.
After restart
Setup
n.
1
Stop the motor by the applying
dynamic brake and then release the
dynamic brake.
n.
2
Coast the motor to a stop without the
dynamic brake.