15.10 Interpolated Position Mode
15-39
15
Object Dictionary
Interpolation Profile Select (2732h) (Mode 2 Object)
This object is used to select the type of interpolation profile to use.
Change the interpolation profile only after execution of the current profile has been completed.
You can change the object when
enable interpolation
(6040h bit 4) is 0.
Data Description
Note: Do not change this value while
enable interpolation
(6040h bit 4) is 1.
Interpolation Data Record for 1st Profile (27C0h) (Mode 2
Object)
This object is used to set the interpolation position reference for the 1st profile in Buffer Strate-
gies for the Interpolated Position Mode.
Set this object only after setting all of the items in
manufacturer interpolation data configuration
for 1st profile
(2730h).
After you set this object, set
enable interpolation
(6040h bit 4) to 1.
Interpolation Data Record for 2nd Profile (27C1h) (Mode 2
Object)
This object is used to set the interpolation position reference for the 2nd profile in Buffer Strat-
egies for the Interpolated Position Mode.
Set this object only after setting all of the items in
manufacturer interpolation data configuration
for 2nd profile
(2731h).
After you set this object, set
enable interpolation
(6040h bit 4) to 1.
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
2732h
0
Interpolation profile
select
USINT
RW
Yes
0 or 1 (default: 0)
No
Value (Method)
Description
0
Uses the 1st profile.
(
interpolation data record for 1st profile
(27C0h) and
manufacturer interpolation data config-
uration for 1st profile
(2730h) are enabled.)
1
Uses the 2nd profile.
(
interpolation data record for 2nd profile
(27C1h) and
manufacturer interpolation data con-
figuration for 2nd profile
(2731h) are enabled.)
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
27C0h
0
Number of entries
USINT
RO
No
254
No
1 to 254
1st set point to
254th set point
DINT
RW
No
-2,147,483,648 to
2,147,483,647
(default:0)
No
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
27C1h
0
Number of entries
USINT
RO
No
254
No
1 to 254
1st set point to
254th set point
DINT
RW
No
-2,147,483,648 to
2,147,483,647
(default:0)
No