9-5
159645-1CD
RE-CHO-A111
9
Alarm
9.3 Display of Alarm Details
FS100
9.3
Display of Alarm Details
Alarm details displaying function indicates the alarm contents breakdown
on the alarm window.
Press [Select] after moving the cursor to the subject alarm on the alarm
window to display its “content”, “cause” and “measure”.
Skip displaying the alarm window to directly display this breakdown
window is possible by specifying the parameter when an alarm occurs.
9.3.1 Parameter
S2C406 Alarm Details Direct Display
0: Invalid / 1: Valid
9.3.2 Display of Alarm Detail Window
Page
Displays
the page number of the alarm whose detail window is currently displayed
/ the total alarm number occurred coincidentally.
Alarm No.
Displays the alarm number with decimal 4 digit.
Sub data
Displays the sub code number defined to each alarm.
Alarm content
Displays the content of the alarm.
Page
Alarm No.
Alarm explanation
Alarm content
Alarm title
Same as alarm
window data.
(Ordinary window)
Measure
Cause
{Return} button
{Retset} button
{Page} button
{Right/Left} button
107 of 348