9-166
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
4495
UNDEFINED ROBOT
CALIBRATION
Sub Code: Control group which
calibration is not completed
Setting error
(1)Check the following settings.
·Before using the coordinated motion, execute the calibration between
manipulators.
4496
PARAMETER ERROR
1
The setting of the manipulator
number is incorrect.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
2
Zero is set for the resolution.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
3
Zero is set in the feedback pulse
parameter.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4
The setting of L-axis ball-screw
data is incorrect.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
5
The setting of U-axis ball-screw
data is incorrect.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
6
Zero or a negative value is set for
MAXPPS.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
7
Zero or a negative value is set for
the maximum acceleration speed.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
8
Zero or a negative value is set for
the maximum deceleration speed.
Setting error
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
268 of 348