9-218
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
Setting error
Check the following settings.
·The tool information
·JOB
·Work
·The speed of JOB
·The acceleration/deceleration speed of ACC and DEC
Connection failure
(1)Reset the alarm
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Module failure (Regenerative
resistor)
(1)Reset the alarm
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Module failure (converter)
(1)Reset the alarm
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Servo control board failure
(1)Reset the alarm
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4973
POSITION ERROR
(COLLISION DETECT)
Setting error
Confirm the settings of the followings.
·The tool information
·Work
4980
DESTINATION PULSE
LIMIT
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4981
DEST PULSE
MECHANICAL LIMIT
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4982
DEST MECHANICAL
INTRF
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4983
DEST MECHANICAL
INTRF
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
4984
DESTINATION SELF-
INTERFERENCE
Setting error
(1)Check the following settings.
·Check the position setting for the step (move instruction) where the alarm
occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
320 of 348