9-129
15964
5-1CD
RE-CHO-A1
11
FS
10
0
3
An error occurred in the
acquisition process of gateway
during the network service data
creation process of the Ethernet
function.
Setting error
(1)Check the following settings.
·The DHCP server operation (If the DHCP is used)
·The network status (If the DHCP is used)
Main CPU board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
4
An error occurred in the
conversion process of gateway
address during the network
service data creation process of
the Ethernet function.
Setting error
(1)Check the following settings.
·The DHCP server operation (If the DHCP is used)
·The network status (If the DHCP is used)
Main CPU board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
6
An error occurred in the
acquisition process of domain
during the network service data
creation process of the Ethernet
function.
Setting error
(1)Check the following settings.
·The DHCP server operation (If the DHCP is used)
·The network status (If the DHCP is used)
Main CPU board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
8
An error occurred in the
acquisition process of host name
during the network service data
creation process of the Ethernet
function.
Setting error
(1)Check the following settings.
·The DHCP server operation (If the DHCP is used)
·The network status (If the DHCP is used)
Main CPU board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace controller.
4300
VERIFY ERROR
(SERVO PARAMETER)
Setting error
(1)Reset the alarm
(2)If the alarm occurs again, check the parameter setting if there were any
parameters which were modified before the alarm.
(3)If the alarm occurs again or when it occurs other than above mentioned (2)
case, contact your YASKAWA representative.
Servo control board failure
(1)Reset the alarm
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.