9-70
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
Main CPU board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4039
MEMORY ERROR
(FORM CUT FILE)
Sub Code: File number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the form cut file in maintenance mode,
and then load the form cut file saved in the external memory device.
Main CPU board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4040
MEMORY ERROR
(SHOCK LEVEL FILE)
Sub Code: File number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the shock level file in maintenance mode,
and then load the shock level file saved in the external memory device.
Main CPU board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4042
MEMORY ERROR
(VISION FILE)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the vision condition file in maintenance
mode, and then load the vision condition file saved in the external memory
device.
Main CPU board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4043
MEMORY ERROR
(VISION CALIBRATION)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the vision calibration file in maintenance
mode, and then load the vision calibration file saved in the external memory
device.
Main CPU board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4046
MEMORY ERROR
(CONVEYOR CALIB
FILE)
Sub Code: File number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the conveyor calibration file in
maintenance mode, and then load the conveyor calibration file saved in the
external memory device.
Main CPU board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
172 of 348