9-140
1596
45-1
C
D
RE-CHO-A1
11
FS10
0
4337
OVERCURRENT
(AMP)
Sub Code: Signifies the axis in
which the alarm occurred
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the following cables.
·Manipulator cable
·Supply cable
Module failure (amplifier)
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Module failure (motor)
(1)Reset the alarm.
(2)If the alarm occurs again, replace the motor.
Servo control board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
4338
REGENERATIVE
TROUBLE
(CONVERTER)
Sub Code: Signifies the axis in
which the alarm occurred
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Module failure (Regenerative
resistor)
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Module failure (converter)
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Servo control board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace controller. Save the CMOS.BIN before
replace controller to be safe.
Overloading
Check that the load does not exceed the allowable limit.
4341
DISLOCATION DETECT
Sub Code: Signifies the axis in
which the alarm occurred
Interference error
Remove the following interferences.
·The interferences to the jigs of Robot.
·The interferences to the jigs of workpieces.
Parts damage
Check the following parts.
·damage of spring
·damage of bushing
Software operation error
occurred
Check the following settings.
·The tool information
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy