9-181
15964
5-1CD
RE-CHO-A1
11
FS
10
0
5
The Corner-R motion cannot be
used for coordinated motion
(with master manipulators).
Setting error
(1)Check the following settings.
·Do not use the Corner-R motion for master manipulators at coordinated
motion.
6
The Corner-R motion cannot be
used for MOVC, MOVS, and
EIMOVC instructions.
Setting error
(1)Check the following settings.
·Use a MOVL instruction when using the Corner-R motion.
8
Different tool numbers are set in a
Corner-R zone (for the Corner-R
middle step and end step).
Setting error
(1)Check the following settings.
·Use the same tool number in a Corner-R zone.
17
The Corner-R motion is disabled
during conveyor tracking.
Setting error
(1)Check the following settings.
·Do not perform the conveyor tracking when using the Corner-R motion.
18
Arithmetic error occurred when
calculating the acceleration and
deceleration time for the Corner-R
operation
Setting error
(1)Check the following settings.
·Do not perform the conveyor tracking when using the Corner-R motion.
20
The Corner-R motion is disabled
to start during continuous motion.
Setting error
(1)Check the following settings.
·Make the setting for the Corner-R radius small.
·set Timer or PL=0 to a previous line.
4540
JOB QUE EMPTY
ERROR
Setting error
(1)Check the following settings.
·Use "CALL QUE" under the condition that the job data is set to the job queue.
4541
INVALID INPUT STRING
(VAL)
1
There was no character string
representing a constant in
character string to be extracted at
VAL instruction execution.
Setting error
(1)Check the following settings.
·Check the settings for the data of the character string to be extracted.
4542
MRESET ERROR
1
An MRESET instruction was
executed while no endless axis
was designated.
Setting error
(1)Check the following settings.
·Set the endless axis.
4543
STACK LESS THAN 0
(JOB CALL)
At job return, an attempt was
made to fetch a data from an
empty job call stack or to stack a
data in the job call stack that is
full.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your YASKAWA representative about occurrence status (operating
procedure).
4544
MID$ INST ERROR
1
The first character of character
string to be extracted is null at
MID$ instruction execution.
Setting error
(1)Check the following settings.
·Check the settings for the data of the character string to be extracted.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
283 of 348