5.7.2
Checking Fuses
There are 16, field replaceable fuses in the system. See figures 5.7.1a and 5.7.2a.
Protects
Label
Value
Location
Size
Type
Coolant and Lube pumps
F1
5A
Computer
module
1 ¼” x ¼” Slow blow
Computer module power supply
F2
4A
3 phase Power supply
F4, F5 and F
3x16A
Electrical
Cabinet
10x38mm
Gg
Spindle AC Drive
F7, F8 and F9
3 x 8A
Transformer Primary
F18 and F19
2 x 12A
Transformer
Axes Servo Drives
F20
16A
Spare 220VAC (Indexer)
F21
10A
24VAC
F22
1A
115VAC-2 (fans and worklight)
F23
4A
115VAC-1 (computer module)
F24
4A
Lube Pump
n/a
5A
Lube pump
5x20mm
Slow blow