Connection problem with USB
cable.
Verify that the USB cable is connected properly from the Computer
Module to the programming panel
Computer Module failure
See Computer diagnostics, Section 5.3
4.3.6
System Will Not Turn On or Boot-Up
Nothing happens when the switch is turned on or the system does not boot-up.
Possible Cause
Check This
Connection problem with the
115VAC cable.
Verify that the 115VAC cable is connected properly to the computer
module.
Computer Module fuse is blown.
Remove fuses and check continuity.
Computer Module failure.
See Computer diagnostics, Section 5.3
4.3.7
System Reboots by Itself
During operation, the screen suddenly blanks and then shows that the system has begun the boot-up
sequence.
Possible Cause
Check This
Connection problem with the
115VAC cable.
Verify that the 115VAC cable is connected properly to the computer
module.
Computer Module failed
See Computer diagnostics, Section 5.3
4.3.8
System Shuts Off
During operation, the system shuts off and will not turn back on.
Possible Cause
Check This
Fuse blown in computer module or
transformer fuses are blown.
Remove fuse and check continuity
Connection problem with the
115VAC cable.
Verify that the 115VAC cable is connected properly to the computer
module.
Computer Module failure
See Computer diagnostics, Section 5.3
4.3.9
Coolant Pump Not Working
The coolant pump is controlled by the AUX button. To test, go to DRO and press the AUX button to turn
the pump on. An “AUX ON” message will appear on the display.
Possible Cause
Check This
The output from the computer
module is not working
Check the F1 fuse coming out of the computer module. There is an
indicator that tells you if it is OK. Turn the coolant pump on and
check for 115 VAC coming out of the computer module. If no
voltage, then replace the computer module
Pump has failed
Check voltage at pump and replace as required.
4.3.10
E-Stop Error
The machine shows a Critical Error 55 when the E-stop button is not pressed.
Содержание TRAK 2OP M11 Mill
Страница 9: ...5 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Страница 10: ...6 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Страница 11: ...7 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Страница 12: ...8 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Страница 13: ...9 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Страница 130: ...1 14 15 1 8 15 12 15 14...