![XYZ Machine Tools TRAK 2OP M11 Mill Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/xyz-machine-tools/trak-2op-m11-mill/trak-2op-m11-mill_safety-installation-maintenance-service-and-parts-list_3848763065.webp)
61
XYZ Machine Tools Ltd
TRAK
2
OP
Installation, Maintenance, Service & Part List Manual
Display Alarm Name Alarm Description
Servo Status
AL007
Over speed
The control speed of the motor exceeds the normal
speed.
Servo Off
AL008
Abnormal
Pulse
Command
The input frequency of the pulse command is over the
allowable value of the hardware interface.
Servo Off
AL009
Excessive
Deviation of
Position
Command
The deviation of position command exceeds the
allowable setting value.
Servo Off
AL011
Encoder Error
The encoder produces abnormal pulse.
Servo Off
AL012
Adjustment
Error
When executing electrical adjustment, the adjusted value
exceeds the allowable value.
Servo Off
AL013
Emergency
Stop
Emergency stop input is activated
Servo Off
AL014
Reverse Limit
Error
Reverse Limit switch input is activated
Servo On
AL015
Forward Limit
Error
Forward Limit switch input is activated
Servo On
AL016
IGBT Overheat The temperature of IGBT is above normal
Servo Off
AL017
Abnormal
EEPROM
Error when DSP accesses EEPROM.
Servo Off
AL018
Abnormal
signal output
The encoder output exceeds the
rated output frequency.
Servo Off
AL019
Serial
Communication
Error
RS-232/485 communication is in error
Servo Off
AL020
Serial
Communication
Time Out
RS-232/485 communication time out
Servo On
AL022
Main Circuit
Power Phase
Loss
Loss of phase of input power
Servo Off
AL023
Early Warning
for Overload
To warn that the servo motor and drive is going to
overload. This alarm will display before ALM006. When
the servo motor reaches the value of P1-56, the motor
will send a warning to the drive.
Servo On
AL024
Encoder initial
magnetic field
error
The magnetic field of the encoder U, V, W signal is in
error.
Servo Off
AL025
Encoder
internal error
The internal memory of the encoder and the internal
counter are in error
Servo Off
AL026
Encoder Data
Error
An encoder data error is detected three times.
Servo Off
AL027
Encoder
internal error
The internal reset of the encoder is in error
Servo Off
AL028
Encoder
internal error
The encoder, U, V, W signals are in error
Servo Off
AL029
Encoder
internal error
Internal address of the encoder is in error
Servo Off
AL030
Motor Torque
Overload
Motor torque exceeds P1-57 for time set by P1-58
Servo Off
Содержание TRAK 2OP M11 Mill
Страница 9: ...5 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...
Страница 10: ...6 XYZ Machine Tools Ltd TRAK 2OP Installation Maintenance Service Part List Manual...